給料機(jī)控制器的調(diào)整方法 |
發(fā)布者:admin 點(diǎn)擊:3510 |
1.開啟分析機(jī)和風(fēng)機(jī),及空壓機(jī),脈沖閥10—20分鐘。
2.把控制器上的主機(jī)電流調(diào)整旋鈕順時針方向調(diào)到底。振幅調(diào)節(jié)旋鈕調(diào)到中間位置。
3.啟動主機(jī),把控制器打到自動位置并打開電源開關(guān),緩慢地關(guān)閉風(fēng)機(jī)風(fēng)閥并注意觀察風(fēng)機(jī)電流達(dá)到60A時固定,向左或向右旋風(fēng)機(jī)電流調(diào)節(jié)旋鈕并注意觀察給料機(jī)電流表,電流表指針左右擺動即可。
4.全部打開風(fēng)機(jī)風(fēng)閥,并快速加大給料量《把振幅調(diào)節(jié)旋鈕順時針方向旋到底即可》同時觀察主機(jī)電流,當(dāng)主機(jī)電流達(dá)到130A時立即逆時針方向旋動主機(jī)電流調(diào)節(jié)旋鈕,給料機(jī)電流表指針左右擺動即可。鎖緊電流調(diào)節(jié)旋鈕。
5.開機(jī)5分鐘左右觀察風(fēng)機(jī)電流是否在60A—65A《順時針方向減小風(fēng)機(jī)電流》微調(diào)風(fēng)機(jī)電流調(diào)節(jié)旋鈕,風(fēng)機(jī)電流穩(wěn)定在60A—65A觀察5—10分鐘,電流符合要求鎖緊風(fēng)機(jī)電流調(diào)節(jié)旋鈕。
6.機(jī)器運(yùn)行中如果有輕微落料,微調(diào)振幅旋鈕《逆時針方向》。
7.注意:電流調(diào)好后一般情況不需要再調(diào)節(jié)主機(jī)和風(fēng)機(jī)電流,控制給料量即可。
中譯英:
1 open analysis machine and the blower, and the air compressor, the pulse valve 10 - 20minutes.
2 controller host current adjusting knob clockwise moved after all. Amplitude adjustment knob to the middle position.
3 boot host, the controller to automatically position and turn on the power switch, slowly closing the fan air valve and observe the fan current reaches 60A fixed, left or right cyclone machine current adjusting knob and observe the feeder current meter, ammeter pointer swing around.
4 all open fan air valve, and the rapid increase of feed quantity" the amplitude adjustment knob clockwise rotation can be observed at the same time the end" current of main host, when the current reaches 130A immediately anti-clockwise rotating hosts a current regulation knob, feeder current meter pointer swing around. Lock current adjusting knob.
5 starting 5 minutes observation fan current is in the 60A - 65A" clockwise to reduce wind mechanical and electrical flow" fine-tuning fan current adjusting knob, fan stable current in60A -65A was observed in 5- 10minutes, current to meet the requirements of locking fan current adjusting knob.
6 the machine is in operation if there is a slight blanking, trimming knob counterclockwise" amplitude".
7 note: current adjusted well in general do not need to adjust host and fan current, control the feeding quantity.